EasyManuals Logo

Keysight Technologies InfiniiVision 3000T X Series User Manual

Keysight Technologies InfiniiVision 3000T X Series
1420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1075 background imageLoading...
Page #1075 background image
:TRIGger Commands 33
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 1075
:TRIGger:TV:POLarity
(see page 1276)
Command Syntax
:TRIGger:TV:POLarity <polarity>
<polarity> ::= {POSitive | NEGative}
The :TRIGger:TV:POLarity command sets the polarity for the TV trigger.
Query Syntax
:TRIGger:TV:POLarity?
The :TRIGger:TV:POLarity? query returns the TV trigger polarity.
Return Format
<polarity><NL>
<polarity> ::= {POS | NEG}
See Also • "Introduction to :TRIGger Commands" on page 1007
• ":TRIGger:MODE" on page 1016
• ":TRIGger:TV:SOURce" on page 1076

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision 3000T X Series and is the answer not in the manual?

Keysight Technologies InfiniiVision 3000T X Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision 3000T X Series
CategoryTest Equipment
LanguageEnglish

Related product manuals