982 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
31 :SYSTem Commands
:SYSTem:DSP
(see page 1276)
Command Syntax
:SYSTem:DSP <string>
<string> ::= quoted ASCII string (up to 75 characters)
The :SYSTem:DSP command writes the quoted string (excluding quotation marks)
to a text box on-screen.
Use :SYSTem:DSP "" to remotely remove the message from the display. (Two sets
of quote marks without a space between them creates a NULL string.)
Press any menu key to manually remove the message from the display.
See Also • "Introduction to :SYSTem Commands" on page 980