:SBUS<n> Commands 29
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 813
:SBUS<n>:M1553:SOURce
(see page 1276)
Command Syntax
:SBUS<n>:M1553:SOURce <source>
<source> ::= {CHANnel<n>}
<n> ::= 1 to (# analog channels) in NR1 format
The :SBUS<n>:M1553:SOURce command sets the source of the MIL-STD 1553
signal.
Use the :TRIGger:LEVel:HIGH and :TRIGger:LEVel:LOW commands to set the
thresold levels for the selected source.
Query Syntax
:SBUS<n>:M1553:TRIGger:SOURce?
The :SBUS<n>:M1553:SOURce? query returns the currently set source of the
MIL-STD 1553 signal.
Return Format
<source><NL>
<source> ::= {CHAN<n>}
<n> ::= 1 to (# analog channels) in NR1 format
See Also • ":TRIGger:LEVel:HIGH" on page 1014
• ":TRIGger:LEVel:LOW" on page 1015
• ":TRIGger:MODE" on page 1016
• "Introduction to :TRIGger Commands" on page 1007