EasyManua.ls Logo

Keysight Technologies InfiniiVision 3000T X Series - :SBUS<n>:SENT:PPULse

Keysight Technologies InfiniiVision 3000T X Series
1420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
828 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
29 :SBUS<n> Commands
:SBUS<n>:SENT:PPULse
(see page 1276)
Command Syntax
:SBUS<n>:SENT:PPULse {{0 | OFF} | {1 | ON}}
The :SBUS<n>:SENT:PPULse command specifies whether the SENT messages are
followed by a pause pulse.
Query Syntax
:SBUS<n>:SENT:PPULse?
The :SBUS<n>:SENT:PPULse? query returns the pause pulse setting.
Return Format
<setting><NL>
<setting> ::= {0 | 1}
See Also ":SBUS<n>:SENT:CLOCk" on page 820
":SBUS<n>:SENT:CRC" on page 821
":SBUS<n>:SENT:DISPlay" on page 822
":SBUS<n>:SENT:FORMat" on page 824
":SBUS<n>:SENT:IDLE" on page 826
":SBUS<n>:SENT:LENGth" on page 827
":SBUS<n>:SENT:SIGNal<s>:DISPlay" on page 829
":SBUS<n>:SENT:SIGNal<s>:LENGth" on page 830
":SBUS<n>:SENT:SIGNal<s>:MULTiplier" on page 832
":SBUS<n>:SENT:SIGNal<s>:OFFSet" on page 833
":SBUS<n>:SENT:SIGNal<s>:ORDer" on page 834
":SBUS<n>:SENT:SIGNal<s>:STARt" on page 836
":SBUS<n>:SENT:SOURce" on page 838
":SBUS<n>:SENT:TOLerance" on page 840
":SBUS<n>:SENT:TRIGger" on page 841
":SBUS<n>:SENT:TRIGger:FAST:DATA" on page 843
":SBUS<n>:SENT:TRIGger:SLOW:DATA" on page 844
":SBUS<n>:SENT:TRIGger:SLOW:ID" on page 846
":SBUS<n>:SENT:TRIGger:SLOW:ILENgth" on page 848
":SBUS<n>:SENT:TRIGger:TOLerance" on page 849

Table of Contents

Related product manuals