:SBUS<n> Commands 29
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 763
:SBUS<n>:FLEXray:TRIGger:FRAMe:CCBase
(see page 1276)
Command Syntax
:SBUS<n>:FLEXray:TRIGger:FRAMe:CCBase <cycle_count_base>
<cycle_count_base> ::= integer from 0-63
The :SBUS<n>:FLEXray:TRIGger:FRAMe:CCBase command sets the base of the
FlexRay cycle count (in the frame header) to trigger on. The cycle count base
setting is only valid when the FlexRay trigger mode is set to FRAME.
Query Syntax
:SBUS<n>:FLEXray:TRIGger:FRAMe:CCBase?
The :SBUS<n>:FLEXray:TRIGger:FRAMe:CCBase? query returns the current cycle
count base setting for the FlexRay frame trigger setup.
Return Format
<cycle_count_base><NL>
<cycle_count_base> ::= integer from 0-63
See Also • "Introduction to :TRIGger Commands" on page 1007
• ":SBUS<n>:FLEXray:TRIGger" on page 758