852 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
29 :SBUS<n> Commands
:SBUS<n>:SPI:BITorder
(see page 1276)
Command Syntax
:SBUS<n>:SPI:BITorder <order>
<order> ::= {LSBFirst | MSBFirst}
The :SBUS<n>:SPI:BITorder command selects the bit order, most significant bit
first (MSB) or least significant bit first (LSB), used when displaying data in the
serial decode waveform and in the Lister.
Query Syntax
:SBUS<n>:SPI:BITorder?
The :SBUS<n>:SPI:BITorder? query returns the current SPI decode bit order.
Return Format
<order><NL>
<order> ::= {LSBF | MSBF}
Errors • "-241, Hardware missing" on page 1235
See Also • "Introduction to :SBUS<n> Commands" on page 697
• ":SBUS<n>:MODE" on page 701
• ":SBUS<n>:SPI Commands" on page 850