838 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
29 :SBUS<n> Commands
:SBUS<n>:SENT:SOURce
(see page 1276)
Command Syntax
:SBUS<n>:SENT:SOURce <source>
<source> ::= {CHANnel<n> | DIGital<d>}
<n> ::= 1 to (# analog channels) in NR1 format
<d> ::= 0 to (# digital channels - 1) in NR1 format
The :SBUS<n>:SENT:SOURce command specifies the input channel for SENT
decode and triggering.
Query Syntax
:SBUS<n>:SENT:SOURce?
The :SBUS<n>:SENT:SOURce? query returns the specified SENT input source.
Return Format
<source><NL>
<source> ::= {CHANnel<n> | DIGital<d>}
<n> ::= 1 to (# analog channels) in NR1 format
<d> ::= 0 to (# digital channels - 1) in NR1 format
See Also ":SBUS<n>:SENT:CLOCk" on page 820
":SBUS<n>:SENT:CRC" on page 821
":SBUS<n>:SENT:DISPlay" on page 822
":SBUS<n>:SENT:FORMat" on page 824
":SBUS<n>:SENT:IDLE" on page 826
":SBUS<n>:SENT:LENGth" on page 827
":SBUS<n>:SENT:PPULse" on page 828
":SBUS<n>:SENT:SIGNal<s>:DISPlay" on page 829
":SBUS<n>:SENT:SIGNal<s>:LENGth" on page 830
":SBUS<n>:SENT:SIGNal<s>:MULTiplier" on page 832
":SBUS<n>:SENT:SIGNal<s>:OFFSet" on page 833
":SBUS<n>:SENT:SIGNal<s>:ORDer" on page 834
":SBUS<n>:SENT:SIGNal<s>:STARt" on page 836
":SBUS<n>:SENT:TOLerance" on page 840
":SBUS<n>:SENT:TRIGger" on page 841
":SBUS<n>:SENT:TRIGger:FAST:DATA" on page 843
":SBUS<n>:SENT:TRIGger:SLOW:DATA" on page 844
":SBUS<n>:SENT:TRIGger:SLOW:ID" on page 846