834 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
29 :SBUS<n> Commands
:SBUS<n>:SENT:SIGNal<s>:ORDer
(see page 1276)
Command Syntax
:SBUS<n>:SENT:SIGNal<s>:ORDer <order>
<s> ::= 1-6, in NR1 format.
<order> ::= {MSNFirst | LSNFirst}
The :SBUS<n>:SENT:SIGNal<s>:ORDer command specifies the nibble order of the
signal being defined, either Most Significant Nibble first, or Least Significant
Nibble first.
Fast Signal definition examples:
Query Syntax
:SBUS<n>:SENT:SIGNal<s>:ORDer?
The :SBUS<n>:SENT:SIGNal<s>:ORDer? query returns the nibble order setting.
Return Format
<order><NL>
<order> ::= {MSNF | LSNF}
See Also ":SBUS<n>:SENT:CLOCk" on page 820
":SBUS<n>:SENT:CRC" on page 821
":SBUS<n>:SENT:DISPlay" on page 822
":SBUS<n>:SENT:FORMat" on page 824
":SBUS<n>:SENT:IDLE" on page 826
":SBUS<n>:SENT:LENGth" on page 827
":SBUS<n>:SENT:PPULse" on page 828
":SBUS<n>:SENT:SIGNal<s>:DISPlay" on page 829
":SBUS<n>:SENT:SIGNal<s>:LENGth" on page 830