:LISTer Commands 20
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 423
:LISTer:DISPlay
(see page 1276)
Command Syntax
:LISTer:DISPlay <value>
<value> ::= {{OFF | 0} | {SBUS1 | ON | 1} | {SBUS2 | 2} | ALL}
The :LISTer:DISPlay command configures which of the serial buses to display in
the Lister, or whether the Lister is off. "ON" or "1" is the same as "SBUS1".
When set to "ALL", the decode information for different buses is interleaved in
time.
Serial bus decode must be on before it can be displayed in the Lister.
Query Syntax
:LISTer:DISPlay?
The :LISTer:DISPlay? query returns the Lister display setting.
Return Format
<value><NL>
<value> ::= {OFF | SBUS1 | SBUS2 | ALL}
See Also "Introduction to :LISTer Commands" on page 421
":SBUS<n>:DISPlay" on page 700