:DIGital<d>:THReshold
(see page 1276)
Command Syntax
:DIGital<d>:THReshold <value>
<d> ::= 0 to (# digital channels - 1) in NR1 format
<value> ::= {CMOS | ECL | TTL | <user defined value>[<suffix>]}
<user defined value> ::= -8.00 to +8.00 in NR3 format
<suffix> ::= {V | mV | uV}
• TTL = 1.4V
• CMOS = 2.5V
• ECL = -1.3V
The :DIGital<d>:THReshold command sets the logic threshold value for all
channels in the same pod as the specified channel. The threshold is used for
triggering purposes and for displaying the digital data as high (above the
threshold) or low (below the threshold).
Query Syntax
:DIGital<d>:THReshold?
The :DIGital<d>:THReshold? query returns the threshold value for the specified
channel.
Return Format
<value><NL>
<value> ::= threshold value in NR3 format
See Also • "Introduction to :DIGital<d> Commands" on page 308
• ":POD<n>:THReshold" on page 587
• ":TRIGger[:EDGE]:LEVel" on page 1033