:CHANnel:LABel
(see page 1276)
Command Syntax
:CHANnel:LABel <source_text><string>
<source_text> ::= {CHANnel1 | CHANnel2 | DIGital<d>}
<d> ::= 0 to (# digital channels - 1) in NR1 format
<string> ::= quoted ASCII string
The :CHANnel:LABel command sets the source text to the string that follows.
Setting a channel will also result in the name being added to the label list.
Query Syntax
:CHANnel:LABel?
The :CHANnel:LABel? query returns the label associated with a particular analog
channel.
Return Format
<string><NL>
<string> ::= quoted ASCII string
NOTE
The :CHANnel:LABel command is an obsolete command provided for compatibility to previous
oscilloscopes. Use the :CHANnel<n>:LABel command (see page 273) or :DIGital<n>:LABel
command (see page 310).