EasyManua.ls Logo

Keysight Technologies InfiniiVision 3000T X Series - :SBUS<n>:SPI:SOURce:FRAMe

Keysight Technologies InfiniiVision 3000T X Series
1420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
:SBUS<n> Commands 29
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 857
:SBUS<n>:SPI:SOURce:FRAMe
(see page 1276)
Command Syntax
:SBUS<n>:SPI:SOURce:FRAMe <source>
<source> ::= {CHANnel<n> | EXTernal} for the DSO models
<source> ::= {CHANnel<n> | DIGital<d>} for the MSO models
<n> ::= 1 to (# analog channels) in NR1 format
<d> ::= 0 to (# digital channels - 1) in NR1 format
The :SBUS<n>:SPI:SOURce:FRAMe command sets the frame source when
:SBUS<n>:SPI:FRAMing is set to CHIPselect or NOTChipselect.
Query Syntax
:SBUS<n>:SPI:SOURce:FRAMe?
The :SBUS<n>:SPI:SOURce:FRAMe? query returns the current frame source for the
SPI serial frame.
Return Format
<source><NL>
See Also "Introduction to :TRIGger Commands" on page 1007
":SBUS<n>:SPI:SOURce:CLOCk" on page 856
":SBUS<n>:SPI:SOURce:MOSI" on page 859
":SBUS<n>:SPI:SOURce:MISO" on page 858
":SBUS<n>:SPI:FRAMing" on page 855

Table of Contents

Related product manuals