676 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
28 :SAVE Commands
:SAVE:IMAGe:INKSaver
(see page 1276)
Command Syntax
:SAVE:IMAGe:INKSaver <value>
<value> ::= {{OFF | 0} | {ON | 1}}
The :SAVE:IMAGe:INKSaver command controls whether the graticule colors are
inverted or not.
Query Syntax
:SAVE:IMAGe:INKSaver?
The :SAVE:IMAGe:INKSaver? query returns a flag indicating whether graticule
colors are inverted or not.
Return Format
<value><NL>
<value> ::= {0 | 1}
See Also • "Introduction to :SAVE Commands" on page 669
• ":SAVE:IMAGe[:STARt]" on page 673
• ":SAVE:IMAGe:FACTors" on page 674
• ":SAVE:IMAGe:FORMat" on page 675
• ":SAVE:IMAGe:PALette" on page 677