:SEARch Commands 30
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 969
:SEARch:SERial:SENT:SLOW:ID
(see page 1276)
Command Syntax
:SEARch:SERial:SENT:SLOW:ID <id>
<id> ::= from -1 (don't care) to 255, in NR1 format.
The :SEARch:SERial:SENT:SLOW:ID command specifies the ID to seach for in the
"Slow Channel Message ID" and "Slow Channel Message ID & Data" trigger
modes. The ID can be from -1 (don't care) to 255 (depending on the message
length).
Query Syntax
:SEARch:SERial:SENT:SLOW:ID?
The :SEARch:SERial:SENT:SLOW:ID? query returns the slow channel ID search
value setting.
Return Format
<id><NL>
<id> ::= from -1 (don't care) to 255, in NR1 format.
See Also • ":SEARch:SERial:SENT:FAST:DATA" on page 966
• ":SEARch:SERial:SENT:MODE" on page 967
• ":SEARch:SERial:SENT:SLOW:DATA" on page 968