396 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
18 :FUNCtion<m> Commands
:FUNCtion<m>:SCALe
(see page 1276)
Command Syntax
:FUNCtion<m>:SCALe <scale value>[<suffix>]
<m> ::= 1 to (# math functions) in NR1 format
<scale value> ::= integer in NR1 format
<suffix> ::= {V | dB}
The :FUNCtion<m>:SCALe command sets the vertical scale, or units per division,
of the selected function. Legal values for the scale depend on the selected
function.
Query Syntax
:FUNCtion<m>:SCALe?
The :FUNCtion<m>:SCALe? query returns the current scale value for the selected
function.
Return Format
<scale value><NL>
<scale value> ::= integer in NR1 format
See Also • "Introduction to :FUNCtion<m> Commands" on page 368