526 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
23 :MEASure Power Commands
:MEASure:CRESt
[<source>] (see
page 532)
:MEASure:CRESt?
[<source>] (see
page 532)
<source> ::= {CHANnel<n>|
FUNCtion<m> | MATH<m>}
<n> ::= 1 to (# analog channels)
in NR1 format
<m> ::= 1 to (# math functions)
in NR1 format
<return_value> ::= the crest
factor value in NR3 format
:MEASure:EFFiciency
(see page 533)
:MEASure:EFFiciency?
(see page 533)
<return_value> ::= percent value
in NR3 format
:MEASure:ELOSs
[<source>] (see
page 534)
:MEASure:ELOSs?
[<source>] (see
page 534)
<source> ::= {CHANnel<n>|
FUNCtion<m> | MATH<m> |
WMEMory<r>}
<n> ::= 1 to (# analog channels)
in NR1 format
<m> ::= 1 to (# math functions)
in NR1 format
<r> ::= 1 to (# ref waveforms) in
NR1 format
<return_value> ::= the energy
loss value in NR3 format
:MEASure:FACTor
[<source1>][,<source2
>] (see page 535)
:MEASure:FACTor?
[<source1>][,<source2
>] (see page 535)
<source1>, <source2> ::=
{CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the power
factor value in NR3 format
:MEASure:IPOWer (see
page 536)
:MEASure:IPOWer? (see
page 536)
<return_value> ::= the input
power value in NR3 format
:MEASure:OFFTime
[<source1>][,<source2
>] (see page 537)
:MEASure:OFFTime?
[<source1>][,<source2
>] (see page 537)
<source1>, <source2> ::=
{CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the time in
seconds in NR3 format
:MEASure:ONTime
[<source1>][,<source2
>] (see page 538)
:MEASure:ONTime?
[<source1>][,<source2
>] (see page 538)
<source1>, <source2> ::=
{CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the time in
seconds in NR3 format
:MEASure:OPOWer (see
page 539)
:MEASure:OPOWer? (see
page 539)
<return_value> ::= the output
power value in NR3 format
Table 101 :MEASure Power Commands Summary (continued)
Command Query Options and Query Returns

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision 3000T X Series and is the answer not in the manual?

Keysight Technologies InfiniiVision 3000T X Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision 3000T X Series
CategoryTest Equipment
LanguageEnglish

Related product manuals