Commands Quick Reference 4
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 119
:SBUS<n>:A429:TRIGger
:RANGe <min>,<max>
(see page 717)
:SBUS<n>:A429:TRIGger
:RANGe? (see page 717)
<min> ::= 8-bit integer in
decimal, <hex>, <octal>, or
<string> from 0-255
<max> ::= 8-bit integer in
decimal, <hex>, <octal>, or
<string> from 0-255
<hex> ::= #Hnn where n ::=
{0,..,9 | A,..,F}
<octal> ::= #Qnnn where n ::=
{0,..,7}
<string> ::= "0xnn" where n::=
{0,..,9 | A,..,F}
:SBUS<n>:A429:TRIGger
:TYPE <condition>
(see page 718)
:SBUS<n>:A429:TRIGger
:TYPE? (see page 718)
<condition> ::= {WSTArt | WSTOp |
LABel | LBITs | PERRor | WERRor |
GERRor | WGERrors | ALLerrors |
LRANge | ABITs | AOBits | AZBits}
Table 26 :SBUS<n>:A429 Commands Summary (continued)
Command Query Options and Query Returns
Table 27 :SBUS<n>:CAN Commands Summary
Command Query Options and Query Returns
n/a :SBUS<n>:CAN:COUNt:ER
Ror? (see page 722)
<frame_count> ::= integer in NR1
format
n/a :SBUS<n>:CAN:COUNt:OV
ERload? (see page 723)
<frame_count> ::= 0 in NR1 format
:SBUS<n>:CAN:COUNt:RE
Set (see page 724)
n/a n/a
n/a :SBUS<n>:CAN:COUNt:SP
EC? (see page 725)
<spec_error_count> ::= integer
in NR1 format
n/a :SBUS<n>:CAN:COUNt:TO
Tal? (see page 726)
<frame_count> ::= integer in NR1
format
n/a :SBUS<n>:CAN:COUNt:UT
ILization? (see
page 727)
<percent> ::= floating-point in
NR3 format
:SBUS<n>:CAN:DISPlay
<type> (see page 728)
:SBUS<n>:CAN:DISPlay?
(see page 728)
<type> ::= {HEXadecimal |
SYMBolic}
:SBUS<n>:CAN:FDSPoint
<value> (see page 729)
:SBUS<n>:CAN:FDSPoint
? (see page 729)
<value> ::= even numbered
percentages from 30 to 90 in NR3
format.
:SBUS<n>:CAN:SAMPlepo
int <value> (see
page 730)
:SBUS<n>:CAN:SAMPlepo
int? (see page 730)
<value> ::= {60 | 62.5 | 68 | 70
| 75 | 80 | 87.5} in NR3 format