Commands Quick Reference 4
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide 145
:TRIGger:MODE <mode>
(see page 1016)
:TRIGger:MODE? (see
page 1016)
<mode> ::= {EDGE | GLITch |
PATTern | TV | DELay | EBURst |
OR | RUNT | SHOLd | TRANsition |
SBUS{1 | 2}}
<return_value> ::= {<mode> |
<none>}
<none> ::= query returns "NONE"
if the :TIMebase:MODE is ROLL or
XY
:TRIGger:NREJect {{0
| OFF} | {1 | ON}}
(see page 1017)
:TRIGger:NREJect?
(see page 1017)
{0 | 1}
:TRIGger:SWEep
<sweep> (see
page 1018)
:TRIGger:SWEep? (see
page 1018)
<sweep> ::= {AUTO | NORMal}
Table 54 General :TRIGger Commands Summary (continued)
Command Query Options and Query Returns
Table 55 :TRIGger:DELay Commands Summary
Command Query Options and Query Returns
:TRIGger:DELay:ARM:SL
OPe <slope> (see
page 1020)
:TRIGger:DELay:ARM:SL
OPe? (see page 1020)
<slope> ::= {NEGative | POSitive}
:TRIGger:DELay:ARM:SO
URce <source> (see
page 1021)
:TRIGger:DELay:ARM:SO
URce? (see page 1021)
<source> ::= {CHANnel<n> |
DIGital<d>}
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
:TRIGger:DELay:TDELay
:TIME <time_value>
(see page 1022)
:TRIGger:DELay:TDELay
:TIME? (see page 1022)
<time_value> ::= time in seconds
in NR3 format
:TRIGger:DELay:TRIGge
r:COUNt <count> (see
page 1023)
:TRIGger:DELay:TRIGge
r:COUNt? (see
page 1023)
<count> ::= integer in NR1 format

Table of Contents