EasyManua.ls Logo

Keysight Technologies InfiniiVision 3000T X Series - Page 36

Keysight Technologies InfiniiVision 3000T X Series
1420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36 Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
1 What's New
:FUNCtion<m>:FFT:FREQuency:
STARt (see page 379)
Lets you set the displayed frequency range using start and stop
frequency values.
:FUNCtion<m>:FFT:FREQuency:
STOP (see page 380)
:FUNCtion<m>:SMOoth:POINts
(see page 397)
Sets the number of smoothing points for the new SMOoth
:FUNCtion<m>:OPERation.
:MEASure:BRATe (see
page 462)
Installs a bit rate measurement on screen or returns the measured
value.
:MEASure:RDSon (see
page 542)
Installs an RDS(on) power measurement on screen or returns the
measured value.
:MEASure:VCESat (see
page 547)
Installs a VCE(sat) power measurement on screen or returns the
measured value.
:POWer:EFFiciency:TYPE (see
page 596)
Specifies the type of power that is being converted from the input
to the output.
:SAVE:RESults:[STARt] (see
page 683)
Saves analysis results to a comma-separated values (*.csv) file on
a USB storage device.
:SAVE:RESults:FORMat:CURSo
r (see page 684)
Specifies whether cursor values will be included when analysis
results are saved.
:SAVE:RESults:FORMat:MASK
(see page 685)
Specifies whether mask statistics will be included when analysis
results are saved.
:SAVE:RESults:FORMat:MEASu
rement (see page 686)
Specifies whether measurement results will be included when
analysis results are saved.
:SAVE:RESults:FORMat:SEARc
h (see page 687)
Specifies whether found search event times will be included when
analysis results are saved.
:SAVE:RESults:FORMat:SEGMe
nted (see page 688)
Specifies whether segmented memory acquisition times will be
included when analysis results are saved.
:SEARch:PEAK Commands (see
page 905)
Commands to set up searching for FFT peaks.
:SBUS<n>:CAN:COUNt:SPEC
(see page 725)
Returns the count for the number of Spec errors (Ack + Form +
Stuff + CRC errors).
:SBUS<n>:CAN:FDSPoint (see
page 729)
Sets the CAN FD sample point.
:SBUS<n>:CAN:SIGNal:FDBaud
rate (see page 733)
Sets the CAN FD baud rate.
:SBUS<n>:CAN:TRIGger:IDFilte
r (see page 738)
Specifies, in certain error and bit trgger modes, whether triggers
are filtered by CAN IDs.
:SBUS<n>:CAN:TRIGger:PATTer
n:DATA:DLC (see page 740)
Specifies the DLC value to be used in the CAN FD data trigger
mode.
Command Description

Table of Contents

Related product manuals