EasyManua.ls Logo

Siemens SCALANCE XM-400 - Unicast-Block

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
107
Requirement
The interface is disabled with the shutdown command.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no switchport
Result
The interface is configured as a router port.
The command prompt is as follows:
cli(config-if_RPort-Gi$$$)#
Activate the interface again with the
no shutdown command.
Further notes
You shut down the interface with the shutdown command.
You activate the interface with the
no shutdown command.
You configure the interface as a switch port with the
switchport command.
You can display the status of this function and other information with the
show ip
interface
command.
3.1.13.22
unicast-block
Description
With this command, you enable the blocking of unknown unicast frames on an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
unicast-block

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Related product manuals