Network protocols
7.2 IPv6 protocol
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
328 Configuration Manual, 06/2016, C79000-G8976-C252-11
Result
The interface ID is configured.
Further notes
You delete the interface ID with the no ipv6 interface-identifier command.
You display this setting and other information with the
show running-config command.
7.2.4.10
no ipv6 interface-identifier
Description
With this command, you delete the interface ID.
Requirement
IPv6 is activated
The interface is an IP interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
no ipv6 interface-identifier <prefix>
The parameter has the following meaning:
Parameter
Description
Range of values / note
prefix
Interface ID
Enter an interface ID.
Result
The interface ID has been deleted.
Further notes
You configure the interface ID with the ipv6 interface-identifier command.
You display this setting and other information with the
show running-config command.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals