Layer 2 management protocols
8.2 IGMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
444 Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
You use IGMP version 3.
You are in the Interface Configuration mode of VLAN.
The command prompt is as follows:
cli(config-if-vlan-$$$)#
Syntax
Call the command without parameter assignment:
ip igmp explicit-tracking
Result
"Explicit Tracking" is enabled on the interface.
Further notes
You configure the IGMP version with the ip igmp version command.
You disable "Explicit Tracking" on an interface with the
no ip igmp explicit-tracking
command.
You display the setting and other information with the
show ip igmp global-config
command.
8.2.3.4
no ip igmp explicit-tracking
Description
With this command, you disable die function "Explicit Tracking" on an interface.
Requirement
You use IGMP version 3.
You are in the Interface Configuration mode of VLAN.
The command prompt is as follows:
cli(config-if-vlan-$$$)#
Syntax
Call the command without parameter assignment:
no ip igmp explicit-tracking

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals