Layer 2 management protocols
8.2 IGMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
444 Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
You use IGMP version 3.
You are in the Interface Configuration mode of VLAN.
The command prompt is as follows:
cli(config-if-vlan-$$$)#
Syntax
Call the command without parameter assignment:
ip igmp explicit-tracking
Result
"Explicit Tracking" is enabled on the interface.
Further notes
You configure the IGMP version with the ip igmp version command.
You disable "Explicit Tracking" on an interface with the
no ip igmp explicit-tracking
command.
You display the setting and other information with the
show ip igmp global-config
command.
8.2.3.4
no ip igmp explicit-tracking
Description
With this command, you disable die function "Explicit Tracking" on an interface.
Requirement
You use IGMP version 3.
You are in the Interface Configuration mode of VLAN.
The command prompt is as follows:
cli(config-if-vlan-$$$)#
Syntax
Call the command without parameter assignment:
no ip igmp explicit-tracking