Layer 2 management protocols
8.5 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
481
Result
The standby connection is assigned a name.
8.5.6.3
no standby connection-name
Description
With this command, you delete the name of a standby connection.
Requirement
You are in the Redundancy Configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call the command without parameters:
no standby connection-name
Result
The name of the standby connection is deleted.
8.5.6.4
standby force-master
Description
With this command, you enable the standby force-master function.
Requirement
HRPis enabed
You are in the Redundancy configuration mode.
The command prompt is:
cli(config-red)#
Syntax
Call the command without parameters:
standby force-master