Layer 3 functions
9.8 Route maps (IPv4 / IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
720 Configuration Manual, 06/2016, C79000-G8976-C252-11
Result
The filter for the value of the metric is deleted.
Further notes
You create a filter for the value of the metric with the match metric command.
You change to the Route maps configuration mode with the command
route-map.
You display the setting and other information with the
show route-map command.
9.8.3.9
match metric-type
Description
With this command, you specify whether or not the routing information for a route map is
filtered based on the type of the metric.
Note
This command is available only with layer 3.
Requirement
You are now in the Route maps configuration mode.
The command prompt is as follows:
cli(config-rmap-$$$)#
Syntax
Call up the command with the following parameters:
match metric-type {inter-area | intra-area | type-1-external | type-2-external }
The parameters have the following meaning:
Parameter
Description
Range of values / note
inter-area
Routes learnt from different areas
-
intra-area
Routes that originate from the same area
-
type-1-external
Routes whose path costs (metric) are made up from the
external path costs and the patch costs to the ASBR
-
type-2-external
Routes with only external path costs (metric)
-
Result
The filter for the type of the metric is created.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals