Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
553
Result
The type of authentication is reset.
Further notes
You enable the authentication with the ip ospf authentication command.
9.2.4.3
ip ospf authentication-key
Description
With this command, you specify the password.
Note
This command is available only with layer 3.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
ip ospf authentication-key <password (8)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
Password
Password Enter a password.
Maximum length: 8 characters
Result
The password is specified.
Further notes
You delete the password with the no ip ospf authentication-key command.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals