EasyManuals Logo

Siemens SCALANCE XM-400 Configuration Manual

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #539 background imageLoading...
Page #539 background image
Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
539
Syntax
Call up the command with the following parameters:
default-information originate always
[metric <metric-value (0-0xffffff)>]
[metric-type <type (1-2)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
metric
Keyword for the metric of the external
standard route.
--
metric-value
Value of the metric
0-0xffffff
metric-type
Keyword for the type of the external
standard route
--
type
Type of the external route
• 1 - type 1
External and internal costs
• 2 - type 2
External costs
Result
The function is enabled.
Further notes
You disable the function with the no default-information originate always command.
9.2.3.16
no default-information originate always
Description
With this command, you disable the function with which a standard route is always
generated for external routes into the OSPF routing domain.
Note
This command is available only with layer 3.
Requirement
You are in the OSPF Router configuration mode.
The command prompt is as follows:
cli(config-ospf)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals