Security and authentication
11.4 IP access control list
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
835
11.4.2.1
ip access-list
Description
With this command, you generate a MAC access control list and change to the ACL standard
configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ip access-list standard<access-list-number(1-128)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
standard
Specifies that a standard access con-
trol list is generated
-
access-list-number
Number of the standard access control
list
1 ... 128
Result
The access control list has been generated.
You are in the ACL Standard configuration mode.
The command prompt is:
cli(config-std-nacl)#
Further notes
You delete the IP access control list with the no ip access-list command.
You exit the ACL Standard configuration mode with the
exit command.
You display the configuration of the access control list with the
show access-lists command.
11.4.2.2
no ip access-list
Description
With this command, you delete an IP access control list.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals