Layer 3 functions
9.7 RIPng (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
703
Parameter
Description
Range of values / note
ospf
Routes learned by OSPF are distribut-
ed.
-
static
Static routes are distributed. -
metric
Keyword for the metric of the external
standard route.
-
integer
Value of the metric (hop counter) 0 ... 16
15 longest possible distance
16: unreachable
route-map
Keyword for a route map.
-
name
Name of the route map.
Maximum of 20 characters
Result
The information forwarded by RIP has been specified.
Further notes
You disable the forwarding with the no redistribute command.
You display the setting and other information with the
show ipv6 rip command.
9.7.3.8
no redistribute
Description
This command specifies which route information is not forwarded by RIP.
Note
This command is available only with layer 3.
Requirement
You are in the RIPng router configuration mode.
The command prompt is as follows:
cli(config-ripng)#
Syntax
Call up the command with the following parameters:
no redistribute {default | connected | ospf | static} [route-map <name(20)>]

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals