Diagnostics
12.2 FMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
909
Requirement
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
rmon power-loss [req]<1/10 dBm> [dem]<1/10 dBm>
The parameters have the following meaning:
Parameter
Description
Range of values / note
req
Specify the value at which you are informed of
the power loss of the connection by a message
of the severity level "Warning"
0 ... -55 dB
Default: -50 dB
dem
Specify the value at which you are informed of
the power loss of the connection by a message
of the severity level "Critical"
0 ... -55 dB
Default: -55 dB
Result
The limits for monitoring the power loss are defined.
Further notes
You enable this function with the fmp command.
You disable this function with the
no fmp command.
You display the status of this function and other information with the
show fmp stauts and
show fmp limit commands.
You define the limit values for the received power with the command
fmp rx-power.
12.2.2.4
fmp rx-power
Description
With this command, you specify the limit values for monitoring the received power per port.
Requirement
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals