Layer 3 functions
9.3 OSPFv3 (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
605
9.3.4.4
no ipv6 ospf dead-interval
Description
With this command, you reset the interval to the default value.
Note
This command is available only with layer 3.
Requirement
The interface is an IPv6 interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call the command without parameter assignment:
no ipv6 ospf dead-interval
Result
The interval is reset.
Further notes
You enable OSPFv3 routing with the ipv6 router ospf command.
You configure the interval with the
no ipv6 ospf dead-interval command.
You display the configuration with the
show ip ospf interface command.
9.3.4.5
ipv6 ospf hello-interval
Description
With his command, you specify the interval between two Hello packets.
Note
This command is available only with layer 3.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals