Network structures
6.4 Passive Listening
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
281
passive-listening bpdu-vlan-flood
Description
With this command you enable forwarding of BPDUs for specific VLANs; in other words to all
ports that are members of a VLAN.
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Call the command without parameters:
passive-listening bpdu-vlan-flood
As default the function is "enabled".
BPDUs for specific VLANs.
You disable this function with the no passive-listening bpdu-vlan-flood command.
You display the status of "passive listening" with the
show passive-listening command.
no passive-listening bpdu-vlan-flood
Description
With this command you enable the flooding of BPDUs to all available ports of the device
regardless of the configured VLANs.
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#