EasyManua.ls Logo

Siemens SCALANCE XM-400 - No Ip Ospf Authentication-Key; Ip Ospf Cost

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
554 Configuration Manual, 06/2016, C79000-G8976-C252-11
9.2.4.4
no ip ospf authentication-key
Description
With this command, you delete the password.
Note
This command is available only with layer 3.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
no ip ospf authentication-key
Result
The password is deleted.
Further notes
You configure the password with the ip ospf authentication-key command.
9.2.4.5
ip ospf cost
Description
With this command, you specify the costs for the OSPF interface.
Note
This command is available only with layer 3.