EasyManua.ls Logo

Siemens SCALANCE XM-400 - Pnio

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
88 Configuration Manual, 06/2016, C79000-G8976-C252-11
The parameters have the following meaning:
Parameter
Description
Range of values / note
vlan
Keyword for a VLAN connection
-
vlan-id
Number of the addressed VLAN 1 … 4094
port-channel
Keyword for a port channel connection
-
port-channel-id
Number of the addressed port channel
1 … 8
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 42)".
Result
The logical interface is deleted.
Further notes
You configure an interface with the interface command.
You display the status and the configuration of the interfaces with the
show interfaces
command.
3.1.12.9
pnio
Description
With this command, you configure the setting for PROFINET after the next restart of the
device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
pnio {off|on}

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Related product manuals