Network protocols
7.2 IPv6 protocol
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
319
Syntax
Call the command without parameter assignment:
no ipv6 unicast-routing
Result
IPv6 routing is disabled. On interfaces on which IPv6 is enabled, stateless autoconfiguration
is performed.
Further notes
You enable IPv6 routing with the ipv6 unicast-routing command.
You display the IPv6 routing table with the
show ipv6 route command.
7.2.4
Commands in the Interface configuration mode
This section describes commands that you can call up in the interface configuration mode.
Depending on the Interface selected, various command sets are available.
In the Global configuration mode, enter the
interface command to change to this mode.
Commands relating to other topics that can be called in the interface configuration mode can
be found in the relevant sections.
If you exit the Interface configuration mode with the
exit command, you return to the
Global configuration mode.
If you exit the Interface configuration mode with the
end command, you return to the
Privileged EXEC mode.
7.2.4.1
ipv6 address
Description
With these commands, you assign an IPv6 address to the interface. The IPv6 address can
be assigned to the IP interface manually or by prefix delegation.
With prefix delegation, the IP interface becomes a DHCPv6 PD sub-client. This forms its
IPv6 address from the prefix name, the prefix and the prefix length.
Requirement
IPv6 is activated
The interface is an IP interface.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals