Layer 2 management protocols
8.5 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
476 Configuration Manual, 06/2016, C79000-G8976-C252-11
8.5.5.3
no ring-redundancy hrpobserver
Description
With this command, you disable the observer.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
no ring-redundancy hrpobserver
Result
The observer is disabled.
Further notes
You enable the observer with the ring-redundancy hrpobserver command.
You can display the status of this function and other information with the
show ring-
redundancy
command.
8.5.5.4
ring-redundancy mode
Description
With this command, you enable the ring redundancy function on a device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ring-redundancy mode {ard | mrpauto | mrpclient | hrpclient | hrpmanager}

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals