Diagnostics
12.5 RMON
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
943
The parameters have the following meaning:
Parameter
Description
Range of values / note
index
Number of the recording
1 ... 65535
buckets
Maximum number of recording inter-
vals
-
bucket-number
Number of recording intervals 1 ... 65535
Default: 50
interval
Duration of an individual recording
interval
-
seconds
Time in seconds 1 ... 3600
Default: 1800
owner
User to which the event is assigned
-
ownername
User name of the user max. 127 characters
Default: monitor
If you do not select any parameter from the parameter list, the default values are used.
Result
The data is recorded.
Further notes
You can display the content of a recording with the show rmon history command.
12.5.3.4
no rmon collection history
Description
With this command, you end the recording of statistical data of the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
no rmon collection history <index(1-52)>

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals