Diagnostics
12.3 Loop detection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
914 Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call the command without parameters:
loopd
Result
The loop detection function is enabled
Further notes
You disable the function with the no loopd command.
You can display the status of this function and other information with the
show loopd
command.
12.3.2.2
no loopd
Description
With this command, you disable the loop detection function.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no loopd
Result
The loop detection function is disabled
Further notes
You enable the function with the loopd command.
You can display the status of this function and other information with the
show loopd
command.