Layer 2 management protocols
8.2 IGMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
448 Configuration Manual, 06/2016, C79000-G8976-C252-11
Result
The period of time is reset.
Further notes
You configure the time with the ip igmp last-member-query-interval command.
You display the setting and other information with the
show ip igmp global-config
command.
8.2.3.9
ip igmp limit
Description
With this command, you define the maximum number of multicast groups that can be
learned using IGMP on an interface. You can define an exception for special multicast
groups.
Requirement
You are in the Interface Configuration mode of VLAN.
The command prompt is as follows:
cli(config-if-vlan-$$$)#
Syntax
Call up the command with the following parameters:
ip igmp limit <value(1-4096)> [except <Group-List id>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
value
Number of multicast groups
1 ... 1000
except
Keyword for an exception
-
Group-List id
ID of the multicast group excluded by the
limit
Specify a valid ID.
Result
The maximum number and exceptions are defined.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals