Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
standby port {<interface-type> <interface-id>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
interface-type
Type or speed of the interface
Enter a valid interface.
interface-id
Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Result
The ports for a standby connection are configured and enabled.
Further notes
You disable the setting with the no standby port command.
You can display the status of this function and other information with the
show ring-
redundancy
command.
8.5.6.7
no standby port
Description
With this command, disable the port for a standby connection on a device.