System time
5.1 System time setting
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
160 Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call up the command with the following parameters:
time dst recurring <name(16)> begin {<week(1-5)> | last} <weekday> <month> <hour> end
{<week(1-5)> | last} <weekday> <month> <hour>
The parameters have the following meaning:
Parameter
Description
Range of values / note
name
Name of the entry
maximum 16 characters
begin
Keyword for the start of daylight saving
time.
-
week
Calendar week in a month
1 … 5
last
Keyword for the last calendar week in a
month
-
weekday
Weekday monday, tuesday, wednesday,
thursday, friday, saturday, sunday
month
Month january, february, march, april,
may, june, july, august, septem-
ber, october, november, decem-
ber
hour
Hour
0 ... 23
end
Keyword for the end of daylight saving
time.
-
Result
The entry for the start and end of daylight saving time was created.
Further notes
You display the settings for the daylight saving time changeover with the show dst info
command.
5.1.2.5
no time dst
Description
With this command you delete the entry for the start and end of daylight saving time with the
specified name. If you do not specify a name as the parameter, all entries are deleted.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals