Security and authentication
11.3 MAC access control list
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
828 Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
A MAC access control list has been created.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
mac access-group <access-list-number(1-128)>{in|out}
The parameters have the following meaning:
Parameter
Description
Range of values / note
access-list-number
Number of the access control list
1 ... 128
in
Specifies that incoming packets are
filtered
-
out
Specifies that outgoing packets are
filtered
-
Result
The packets are filtered according to the access control list (ACL).
Further notes
You disable the setting with the no mac access-group command.
You display the statistical data of the access control list with the
show access-lists
command.
11.3.3.2
no mac access-group
Description
With this command, you disable the access control of the packets of an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals