Network structures
6.2 Link aggregation
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
229
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
If you do not select an interface, information for all interfaces is displayed.
The interface-specific information for a port channel is displayed.
Note
When a port is assigned to a link aggregation but is n
ot active (e.g. link down), the values
displayed may differ from the values configured for the link aggregation.
If the port in the link aggregation becomes active, individual port configurations such as DCP
forwarding are overwritten with the configured v
alues of the link aggregation.
This command shows the information about the settings and information about the ports
involved in the link aggregation. The number of sent and received packets is also displayed.
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Call up the command with the following parameters:
show lacp [<port-channel(1-8)>]{counters|neighbor[detail]}
The parameters have the following meaning:
Number of the Channel-Group
Shows the values of the counters
Displays information on neighbor ports
Displays detailed information on neigh-
-
If you do not select a port channel, information for all available interfaces is displayed.