Layer 3 functions
9.5 VRRPv3 (IPv4 / IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
662 Configuration Manual, 06/2016, C79000-G8976-C252-11
9.5.5.3
vrrp associated-ip
Description
With this command, you specify which IP addresses the virtual router monitors.
Note
This command is available only with layer 3.
Requirement
You are in the VRRP3 Interface configuration mode.
The command prompt is as follows:
cli(config-vrrp-v3-if-$$$)#
Syntax
Call up the command with the following parameters:
vrrp <vrid(1-255)> associated-ip [{ ipv4 <ip_addr> | ipv6 <ip6_addr> }]
The parameters have the following meaning:
Parameter
Description
Range of values / note
vrid
ID of the virtual router
1 ... 255
ipv4
Keyword for IPv4 address
-
ip_addr
IPv4 address
Enter a valid IPv4 address.
ipv6
Keyword for IPv6 address
-
ip6_addr
IPv6 address
Enter a valid IPv6 address.
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Result
The IP addresses are specified.
Further notes
You can create a maximum of 52 virtual IPv4/IPv6 addresses.
You configure a VRRP3 interface with the
interface command.
You remove an IP address with the
no vrrp associated-ip command.
You display the IP addresses with the
show vrrp3 command.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals