EasyManuals Logo

Siemens SCALANCE XM-400 Configuration Manual

Siemens SCALANCE XM-400
960 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #477 background imageLoading...
Page #477 background image
Layer 2 management protocols
8.5 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
477
The parameters have the following meaning:
Parameter
Description
ard
Enables the automatic redundancy mode (Automatic Redundancy Detec-
tion)
mrpauto
Enables the automatic MRP manager
mrpclient
Enables ring redundancy with the MRP protocol as client
hrpclient
Enables ring redundancy with the HRP protocol as client
hrpmanager
Enables ring redundancy with the HRP protocol in ring redundancy manag-
er mode
Result
The ring redundancy function is enabled and the redundancy mode is selected.
Further notes
You disable the ring redundancy function with the no ring-redundancy command.
8.5.5.5
no ring-redundancy
Description
With this command, you disable the ring redundancy function on a device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no ring-redundancy
Result
The ring redundancy function is disabled.
Further notes
You enable the ring redundancy function with the ring-redundancy mode command.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals