System time
5.2 NTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
164 Configuration Manual, 06/2016, C79000-G8976-C252-11
Result
The connection to a server is configured on the NTP client.
Further notes
You delete the connection to a server with the no ntp server command.
5.2.3.2
no ntp server
Description
With this command, you delete the connection to a server on the NTP client.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call up the command with the following parameters:
no ntp server <integer (1-3)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
integer
Number of the NTP server.
1 ... 3
Result
The connection to a server is deleted on the NTP client.
Further notes
You configure the connection to a server with the ntp server command.
5.2.3.3
ntp time diff
Description
With this command, you configure the time difference between the device and the NTP
server.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals