Layer 3 functions
9.3 OSPFv3 (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
604 Configuration Manual, 06/2016, C79000-G8976-C252-11
9.3.4.3
ipv6 ospf dead-interval
Description
With this command, you specify the time that can elapse before the neighbor router is
assumed to have "failed". This means that no more Hello packets were received from it
during this time.
Note
This command is available only with layer 3.
Requirement
The interface is an IPv6 interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
ipv6 ospf dead-interval <interval>
The parameter has the following meaning:
Parameter
Description
Range of values / note
interval
Interval in seconds 1 ... 65535
Default: 40
The value must be four times the hello interval.
The routers located on the same link must have the
same interval.
Result
The interval is specified.
Further notes
You display the configuration with the show ip ospf interface command.
You enable OSPFv3 routing with the
ipv6 router ospf command.
You can reset the interval to the default with the
no ipv6 ospf dead-interval command.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals