Network structures
6.3 Spanning Tree
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
268 Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call the command without parameters:
spanning-tree loop-guard
Result
The "Spanning Tree Loop Guard" function is enabled.
Further notes
You disable the setting with the no spanning-tree loop-guard command.
You can display the status of this function and other information with the following
commands:
show spanning-tree detail
show spanning-tree active detail
show spanning-tree interface
6.3.5.13
no spanning-tree loop-guard
Description
This function prevents alternative ports or root ports becoming designated ports if there is a
disruption of a one-way link.
With this command, you disable the function.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no spanning-tree loop-guard
Result
The "Spanning Tree Loop Guard" function is disabled.

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals