Layer 3 functions
9.8 Route maps (IPv4 / IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
730 Configuration Manual, 06/2016, C79000-G8976-C252-11
9.8.3.19
set metric
Description
With this command, you specify whether the routing information is forwarded with a changed
metric.
Note
This command is available only with layer 3.
Requirement
You are now in the Route maps configuration mode.
The command prompt is as follows:
cli(config-rmap-$$$)#
Syntax
Call up the command with the following parameters:
set metric <value(0-0xffffff)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
value
Value of the metric 0 ... 0xffffff
Enter the new value for the metric with which the routing
information will be forwarded.
You can enter the value in decimal or hexadecimal.
Result
The routing information is forwarded with a changed metric.
Further notes
You delete the setting that the metric of the routing information is changed with the no set
metric
command.
You change to the Route maps configuration mode with the command
route-map.
You display the setting and other information with the
show route-map command.