Parameter
Description
Range of values / note
ip-acl
Keyword for an IP access control list
-
acl-id
Number of the Access Control List -
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
If you do not select any parameters from the parameter list, the default value (both) is used.
Result
The source for the mirroring of a port is deleted.
Further notes
You configure the source for mirroring a port with the monitor session ... source command.
You end and delete a session with the
no monitor session command.
You display the configuration settings with the
show monitor session command.
12.4.2.9
no monitor session
Description
With this command, you delete the monitor session.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no monitor session<session-id(1-7)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
session-id
Number of the session
7 parallel sessions are possible only
with port-based mirroring and their
ports must not overlap.
1 ... 7

Table of Contents

Other manuals for Siemens SCALANCE XM-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XM-400 and is the answer not in the manual?

Siemens SCALANCE XM-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XM-400
CategorySwitch
LanguageEnglish

Related product manuals