Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
134 Configuration Manual, 06/2016, C79000-G8976-C252-11
3.5.3.2
no poe active
Description
With this command, you deactivate PoE for the interface in whose interface configuration
mode you are currently working.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no poe active
Result
PoE is deactivated for the corresponding interface.
3.5.3.3
poe custom maxpwr
Description
With this command you set the maximum power that a port makes available to supply a
connected device.
This value is taken into account when the function is enabled with the
poe custom maxpwr
active
command.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameter:
poe custom maxpwr <integer(0-30)>